METSEEM4236B401 | Enercept Meter, class 0.2S, Modbus/BACnet RS485, Split Core 400A, ANSI wire code | Square D by Schneider Electric
Get Special Pricing!
Log In or Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Square DSKU: METSEEM4236B401

Web Price:

$1,125.26
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms
Image for Technical Expert

Speak With a Technical Expert

Call (847) 773-0645

Hours: 9am - 5pm CDT M-F

METSEEM4236B401 | Enercept Meter, class 0.2S, Modbus/BACnet RS485, Split Core 400A, ANSI wire code | Square D by Schneider Electric

Square D | METSEEM4236B401
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to METSEEM4236B401

Documents and manuals

Square D METSEEM4236B401 Documents

Overview

Details for METSEEM4236B401

Enercept Meter, class 0.2S, Modbus/BACnet RS485, Split Core 400A, ANSI wire code

The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 400 A split-core current transformers. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.

Specifications

range
PowerLogic
product name
PowerLogic EM4200
device short name
Enercept
Product or Component Type
Energy meter
Type of Cable
ANSI cable
Device Application
Power monitoring
metering type
Active;reactive;apparent energy (signed;four quadrant);Apparent power S;S1;S2;S3;Demand power P;Q;S;Active power P;P1;P2;P3;Reactive power Q;Q1;Q2;Q3;Power factor;Average current Iavg;Peak demand power PM;QM;SM;Frequency;Voltage U21;U32;U13;V1;V2;V3
accuracy class
Class 1 ANSI C12.1;Class 1S IEC 62053-22
measurement accuracy
1 %
measurement current
0…400 A
measurement voltage
90 V AC 45...65 Hz minimum per phase;480 V AC 45...65 Hz between phases;300 V AC 45...65 Hz between phase and neutral
frequency measurement range
45…65 Hz
Network Frequency
50 Hz;60 Hz
Line Rated Current
400 A
Display Type
Without Display
local signalling
Status LED green and red);Line fault 3 LED green;orange and red);Dial pointer indication LED Yellow);RX/TX 2 LED green;orange and red)
Signal
split core current transducer 0.333 V 33 kOhm);voltage single phase 2.5 MOhm);voltage phase to phase 5 MOhm)
number of inputs
0
Number of Outputs
0
communication port protocol
Modbus RTU 9600 bauds...115200 bauds (automatic detection);BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
communication of data
Remote control orders;Total energy;Net energy
Demand intervals
External synchronisation to communication;Fixed or rolling block
provided equipment
Bracket for support;Hook;Split core current transducer 3;Fuse
connections - terminals
Input/output plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²);Current transformer plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²);Communication plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²)
wire stripping length
0.24 in (6 mm)
Mounting Mode
By screws;Clip-on;By hook
mounting support
Enclosure;DIN rail
Standards
EN 61010-1;UL 61010-1;CAN/CSA C22.2 No. 61010-1-12
product certifications
CE EN 61010-1;CULus UL 61010-1;BTL;ANSI
Width
1.84 in (46.63 mm)
depth
1.41 in (35.81 mm)
Height
6.00 in (152.36 mm)
measurement category
Category III 277 V;Category III 300 V
electromagnetic compatibility
Conducted and radiated emissions FCC Part 15 class A;Conducted and radiated emissions EN 61000-6-4;Conducted and radiated emissions EN 61326 + A1;Immunity to conducted disturbances EN 61000-6-2;Immunity to conducted disturbances EN 61326-1;Immunity to radiated fields EN 61000-6-2;Immunity to radiated fields EN 61326-1
IP degree of protection
IP20 IEC 60529
relative humidity
0…95 %
pollution degree
2
ambient air temperature for operation
-22…158 °F (-30…70 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Operating altitude
< 9842.52 ft (3000 m)
Category
09791-POWERLOGIC ENERCEPT POWER METER
Discount Schedule
PL1
GTIN
3606489564711
Returnability
No
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
82.41 oz (2336.36 g)