Get Special Pricing!
METSEPM5110 | PM5110 Power Meter w Modbus - upto 15th H - 1DO 33alarms - flush mount | Square D by Schneider Electric
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to METSEPM5110
Overview
Details for METSEPM5110
PM5110 Power Meter w Modbus - upto 15th H - 1DO 33alarms - flush mount
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has one digital pulse output and 33 configurable alarms. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 13.4 onces (380 g).Specifications
- range
- PowerLogic
- product name
- PowerLogic PM5000
- device short name
- PM5110
- Product or Component Type
- Power meter
- power quality analysis
- up to the 15th harmonic
- Device Application
- Power monitoring
- type of measurement
- Current;Voltage;Frequency;Power factor;Energy;Active and reactive power
- supply voltage
- 90...450 V AC 45...65 Hz;100...300 V DC
- Network Frequency
- 50 Hz;60 Hz
- Line Rated Current
- 1 A;5 A
- type of network
- 1P + N;3P + N;3P
- maximum power consumption in VA
- 10 VA 415 V
- ride-through time
- 80 ms 120 V AC typical;100 ms 230 V AC typical;100 ms 415 V AC typical;50 ms 125 V DC typical
- Display Type
- Monochrome graphic LCD
- Display Resolution
- 128 x 128 pixels
- sampling rate
- 64 samples/cycle
- measurement current
- 50…8500 mA
- analogue input type
- voltage 5 MOhm);current <= 0.3 mOhm)
- measurement voltage
- 35…760 V AC 45...65 Hz between phases;20…440 V AC 45...65 Hz between phase and neutral
- frequency measurement range
- 45…65 Hz
- number of inputs
- 0
- measurement accuracy
- Active energy +/- 0.5 %;Reactive energy +/- 2 %;Active power +/- 0.5 %;Apparent power +/- 0.5 %;Frequency +/- 0.05 %;Power factor +/- 0.5;Current +/- 0.5 %;Voltage +/- 0.5 %;Apparent energy +/- 0.5 %;Reactive power +/- 2 %
- accuracy class
- Class 0.5S active energy IEC 62053-22
- Number of Outputs
- 1 digital
- communication port protocol
- Modbus RTU and ASCII 9.6;19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V;JBUS
- communication port support
- RS485
- data recording
- Time stamping;Min/max of instantaneous values
- connections - terminals
- Voltage circuit screw terminal block4;Control circuit screw terminal block2;Current transformer screw terminal block6;Input/output circuit screw terminal block6;RS485 link screw terminal block4
- Mounting Mode
- Flush-mounted
- mounting support
- Framework
- Standards
- UL 61010-1;EN 50470-3;EN 50470-1;IEC 62053-22;IEC 60529;IEC 62053-24;IEC 61557-12
- product certifications
- CE IEC 61010-1;CULus UL 61010-1
- Width
- 3.78 in (96 mm)
- depth
- 2.83 in (72 mm)
- Height
- 3.78 in (96 mm)
- Net Weight
- 13.40 oz (380 g)
- electromagnetic compatibility
- Voltage dips and interruptions immunity testclass A IEC 61000-4-11;Limits for harmonic current emissionsclass A IEC 61000-3-2;Electrostatic dischargelevel 4 IEC 61000-4-2;Conducted RF disturbanceslevel 3 IEC 61000-4-6;Magnetic field at power frequencylevel 4 IEC 61000-4-8;Conducted and radiated emissionsclass B EN 55022;Immunity to conducted disturbances 150 kHz...80 MHz IEC 61000-4-6;Electrical fast transient/burst immunity test IEC 61000-4-4;Radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3;Surge immunity test IEC 61000-4-5;Voltage dips and interruptions immunity test IEC 61000-4-11
- IP degree of protection
- Display IP54 IEC 60529;Rear IP30 IEC 60529
- relative humidity
- 5…95 % 122 °F (50 °C) non-condensing
- pollution degree
- 2
- ambient air temperature for operation
- -13…158 °F (-25…70 °C) meter;-4…158 °F (-20…70 °C) display;-13…-4 °F (-25…-20 °C) with reduced performance) display
- Ambient Air Temperature for Storage
- -40…185 °F (-40…85 °C)
- operating altitude
- 6561.68 ft (2000 m) CAT III
- Category
- 09777-POWERLOGIC PM5000 HARDWARE
- Discount Schedule
- PL1
- GTIN
- 3606480613982
- Returnability
- No
- Country of origin
- IN
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 4.51 in (11.467 cm)
- Package 1 Width
- 5.11 in (12.979 cm)
- Package 1 Length
- 4.94 in (12.544 cm)
- Package 1 Weight
- 15.84 oz (449.0 g)
- Unit Type of Package 2
- S03
- Number of Units in Package 2
- 12
- Package 2 Height
- 11.81 in (30.0 cm)
- Package 2 Width
- 11.81 in (30.0 cm)
- Package 2 Length
- 15.75 in (40.0 cm)
- Package 2 Weight
- 15.85 lb(US) (7.19 kg)
- Unit Type of Package 3
- P12
- Number of Units in Package 3
- 288
- Package 3 Height
- 41.34 in (105.0 cm)
- Package 3 Width
- 31.50 in (80.0 cm)
- Package 3 Length
- 47.24 in (120.0 cm)
- Package 3 Weight
- 455.03 lb(US) (206.4 kg)
Reviews
Recently Viewed
New Arrivals
171CBU98090 | UNITY M1E SERIAL 232/485 | Square D by Schneider Electric
Brand: Square D
SKU: 171CBU980902601AG2 | DRUM SWITCH 600VAC 2HP A +OPTION | Square D by Schneider Electric
Brand: Square D
SKU: 2601AG28911DPSO42V09 | Definite Purpose Starter, 40A, Open, 220V 50 Hz, 208-240V 60 Hz, 2-Poles, 1-Phase | Square D by Schneider Electric
Brand: Square D
SKU: 8911DPSO42V099001BWAEQ3439G3 | PENDANT STATION 600VAC 5A T-BW SPECIAL | Square D by Schneider Electric
Brand: Square D
SKU: 9001BWAEQ3439G3People Also Searched
METSEPM5110
Square D METSEPM5110
METSEPM5110 price
Square D METSEPM5110 price